PROJECTS                                                                                                   << Back

Power Plant Boiler Stack 85 mtr. High (Chimney Structure)

   
   
 
 

Methodology designed for restoring the structure:

Structural repairs items to shell chimney structure. Migrating Corrosion Inhibitor application to reduce corrosion in inner reinforcement.
 
Nature of the structure:
RCC Cylindrical shell tapering to top with bottom diameter 7.5 mtr and top diameter 3.5 mtr.
 
Exposure Conditions:
Structural cracks in concrete to shell portion, Reinforcement exposed at few places.
 
Reason of Distress:
Environmental attack, Aging, may be poor quality of construction.
 
Specialty Treatment :
Grouting and application with MCI, Protective coating to entire structure to enhance serviceability.
 
   
 